Engineering & Consulting Services

Commercial Feasibility
ROI/Financial analysis.

Liasoning & Compliances
BANKING/MSEDCL/PWD/MEDA ETC

Scope of Supply
In project work client must be very cleared in supply and execution scope

Approvals…PWD/MSEDCL/CLIENT

Project Drawings and Layouts

Project Management Services….

Engineering, Design Inputs and Drawings
Before project execution all design drawings need to be prepared. Structural, Civil, Electrical single line diagrams, LA and Earth pit locations helps to installation and execution. Design civil foundations, gutters, piles, Room, road, boundary walls and fencings, gate with all details and specifications etc.

Data Analysis and Technical Feasibility
Advance action must be initiated on Acquisition of land, securing essential clearances from Electrical supply authority, identify technical collaborators/consultants, Arranging infrastructure facilities, Preliminary design and engineering requirements.

Detailed Project Report Preparation….Detailed Project data analysis/BOM/Commercial and Technical Feasibility Report/ROI/Financial analysis.
Electricals Flow Design and SLD Electricity
After initial Survey and data collection one has to work out the feasible Solar Plant Capacity kWp based on consumptions and statutory requirements. Solar utility projects are typically a combination of both low voltage DC and medium voltage AC electrical systems. Bridging the design details from DC to AC and creating cohesion throughout the design is one of the unique features.
There is an exciting trend towards offering solar array wiring of up to 1500 Volts DC on ground-based systems and 1000 Volts DC on rooftop solar systems. Design and draw single line wiring of DC along with conduiting and Cable trays. Include AJB, MJB, DCDB with suitable fuses and SPDs. In ground mounted plant design adequate wide and deep trenches with suitable covering of the trench.
Fix the final suitable locations of AJB, MIB, DCDB, Inverter, ACDB and hook up the AC supply to existing input supply of Client. Design adequate capacity of Net Metering system and apply to Power Supply Authority for statutory clearances and approvals before installation completes. Also design layout for LA system along with layout and details, the LA surge must be grounded into ground. Some time looking to building size and Land orientation more than one LA can be designed. The DC earthing is also important therefore prepare DC earthing layout along with the material specifications. The earthing strip/Wire/ Bar may be of Copper, GI, AI must be connected to all Modules, structure, AJB/MJB/DCDB, and ground in soil through DC earth pit. Design AC earthing separate and it must be be connected to AC out put side of Inverter, ACBD and Control Panel, Metering systems and ground in to AC earth Pit.
Quick Links
Works address
5th Floor 508 Office, S No 52, Baner Business Bay, Pashan - Sus Rd, Pune Banglore Highway Pashan Exit, behind Audi, off Mumbai, Mohan Nagar Co-Op Society, Baner, Pune, Maharashtra 411045
Phone
Sales
+917219005592
O&M
+917219005549
info@renewxpert.com